I24-Microfocus Macromolecular Crystallography
VMXi-Versatile Macromolecular Crystallography in situ
|
Pierre
Aller
,
Juan
Sanchez-Weatherby
,
Abbey
Telfer
,
Robert
Bosman
,
Nicholas
Devenish
,
Philip
Hinchliffe
,
Sam
Horrell
,
Jophy
Ip
,
Richard
Littlewood
,
Andrew
Male
,
Eva
Gimenez-Navarro
,
Urszula
Neuman
,
Jos J. A. G.
Kamps
,
David
Omar
,
Laura
Parkinson
,
Muthraj
Pandi
,
Nico
Rubies
,
James
Sandy
,
Anastasya
Shilova
,
James
Spencer
,
Jonathan
Spiers
,
John P.
Sutter
,
Amy J.
Thompson
,
Catherine L.
Tooke
,
Ben
Williams
,
Tiankun
Zhou
,
Michael A.
Hough
,
Allen M.
Orville
Open Access
Abstract: Time-resolved X-ray crystallography is experiencing a resurgence, in part because of serial methods that readily allow scientists to create stop-motion movies of the macromolecular functions of photoactivation, enzyme-catalysed reactions and ligand-induced conformational changes triggering further downstream signalling events. While some reactions can be initiated with light, either naturally or using photocaged compounds, a more generally applicable approach is to mix microcrystals with reagents at varying time points prior to exposure to the X-ray beam. A powerful approach has been to combine droplet-on-demand `tape drive' sample delivery with X-ray emission spectroscopy (XES) that correlates atomic structure with the electronic states of metal ions within the sample. To the best of our knowledge, such a combined methodology has not been deployed previously on a synchrotron beamline but has been restricted to X-ray free-electron lasers. Here we describe two independent prototype experiments along the development pathway to a combined droplet-on-demand diffraction and XES system on the microfocus synchrotron beamline VMXi at Diamond Light Source. We demonstrate the collection of a high-quality serial diffraction data set from microcrystals within droplets having a volume of hundreds of picolitres deposited on a moving tape. In separate experiments on VMXi, we collected XES data from microcrystals of a copper enzyme delivered using a high-viscosity extruder. Together, these results demonstrate the feasibility of combined droplet-on-demand serial crystallography and XES experiments using a third-generation synchrotron beamline.
|
Sep 2026
|
|
I24-Microfocus Macromolecular Crystallography
|
Jos J. A. G.
Kamps
,
Philip
Hinchliffe
,
Johan
Glerup
,
Emily I.
Freeman
,
Pauline A.
Lang
,
Catherine
Tooke
,
Michael
Beer
,
Laura
Parkinson
,
Do-Heon
Gu
,
Sehan
Park
,
Nicholas
Devenish
,
Tiankun
Zhou
,
Anastasya
Shilova
,
Samanpreet
Kaur
,
Patrick
Rabe
,
Christopher J.
Schofield
,
James
Spencer
,
Jaehyun
Park
,
Robin L.
Owen
,
Allen M.
Orville
,
Pierre
Aller
Diamond Proposal Number(s):
[25260]
Open Access
Abstract: We describe the design and implementation of a drop-on-fixed-target method for time-resolved serial crystallography at both synchrotron and XFEL facilities. A piezoelectric droplet dispensing pipette is employed for addition of picolitre volume aqueous droplets (∼40–90 pl; ∼40–55 µm diameter sphere), containing (co-)substrate(s) or ligand(s), onto enzyme microcrystals previously loaded into the trapezoidal wells of an etched crystalline silicon fixed-target chip containing 25 600 wells in a high-density, square grid with 125 µm centre-to-centre well spacing. These features demand exquisite accuracy and thereby constrain motion controls to enable robust time-resolved crystallographic studies. The system was tested with three enzyme systems, comprising lysozyme and two β-lactamases, CTX-M-15 and AmpCEC. Mitigation strategies for cross-well contamination, including the implementation of interleaved controls, are described; the overall performance of the system at synchrotron and X-ray free-electron laser facilities was evaluated. This drop-on-fixed-target method is a reliable framework for time-resolved crystallography and will improve the consistency of measurements across facilities.
|
Jul 2026
|
|
|
|
Lewis J.
Williams
,
Jos J. A. G.
Kamps
,
Adrian M. V.
Brânzanic
,
Maria
Lehene
,
Kristoffer J. M.
Lundgren
,
Ulf
Ryde
,
Kuntal
Chatterjee
,
Margaret D.
Doyle
,
Philipp S.
Simon
,
Hiroki
Makita
,
Amy J.
Thompson
,
Aaron S.
Brewster
,
Tiankun
Zhou
,
Marina
Lucic
,
Michael T.
Wilson
,
Pierre
Aller
,
Juan
Sanchez-Weatherby
,
Leland
Gee
,
Sebastian
Dehe
,
Sandra
Mous
,
Junko
Yano
,
Vittal K.
Yachandra
,
Michael A.
Hough
,
Allen M.
Orville
,
Jan F.
Kern
,
Radu L.
Silaghi-Dumitrescu
,
Jonathan A. R.
Worrall
Open Access
Abstract: The use of X-ray structures to determine and interpret the ferryl iron-oxygen bond order in molecular oxygen-activating heme enzymes has, in the past, been controversial. This has mainly stemmed from the susceptibility of ferryl species to X-ray-induced electronic state changes. In this work we establishe using time-resolved serial femtosecond X-ray crystallography (tr-SFX) on a dye-decolourising peroxidase that the ferryl intermediate species (Compounds I and II) captured following in situ mixing of microcrystals with H2O2 have single, rather than the double bond character expected. X-ray emission validated tr-SFX data with quantum refinement, time-dependent-DFT calculations and QM/MM geometry optimizations together support the concept that the single iron-oxygen bond character is not an indication of ferryl reduction or a protonated form (FeIV-OH) but is instead attributed to the existence of accessible excited states possessing ferric-oxyl (FeIII–O•–) character. Such states offer insight into the nature of ferryl heme.
|
Feb 2026
|
|
|
|
Abstract: Dynamic structural biology enables studying biological events at the atomic scale from 10’s of femtoseconds to a few seconds duration. With the advent of X-ray Free Electron Lasers (XFELs) and 4th generation synchrotrons, serial crystallography is becoming a major player for time-resolved experiments in structural biology. Despite significant progress, challenges such as obtaining sufficient amounts of protein to produce homogeneous microcrystal slurry, remain. Given this, it has been paramount to develop instrumentation that reduces the amount of microcrystal slurry required for experiments. Tape-drive systems use a conveyor belt made of X-ray transparent material as a motorized solid-support to steer deposited microcrystals into the beam. For efficient sample consumption on-demand ejectors can be synchronized with the X-ray pulses to expose crystals contained in droplets deposited on the tape. Reactions in the crystals can be triggered via various strategies, including pump-probe, substrate/ligand mixing, or gas incubation in the space between droplet ejection and X-ray illumination. Another challenge in time-resolved serial crystallography is interpreting the resulting electron density maps. This is especially difficult for metalloproteins where the active site metal is intimately involved in catalysis and often proceeds through multiple oxidation states during enzymatic catalysis. The unrestricted space around tape-drive systems can be used to accommodate complementary spectroscopic equipment. Here, we highlight tape-drive sample delivery systems for complementary and simultaneous X-ray diffraction (XRD) and X-ray emission spectroscopy (XES) measurements. We describe how the combination of both XRD and XES is a powerful tool for time-resolved experiments at XFELs and synchrotrons.
|
Oct 2024
|
|
I23-Long wavelength MX
|
Yishun
Lu
,
Ramona
Duman
,
James
Beilsten-Edmands
,
Graeme
Winter
,
Mark
Basham
,
Gwyndaf
Evans
,
Jos J. A. G.
Kamps
,
Allen M.
Orville
,
Hok-Sau
Kwong
,
Konstantinos
Beis
,
Wesley
Armour
,
Armin
Wagner
Open Access
Abstract: rocessing of single-crystal X-ray diffraction data from area detectors can be separated into two steps. First, raw intensities are obtained by integration of the diffraction images, and then data correction and reduction are performed to determine structure-factor amplitudes and their uncertainties. The second step considers the diffraction geometry, sample illumination, decay, absorption and other effects. While absorption is only a minor effect in standard macromolecular crystallography (MX), it can become the largest source of uncertainty for experiments performed at long wavelengths. Current software packages for MX typically employ empirical models to correct for the effects of absorption, with the corrections determined through the procedure of minimizing the differences in intensities between symmetry-equivalent reflections; these models are well suited to capturing smoothly varying experimental effects. However, for very long wavelengths, empirical methods become an unreliable approach to model strong absorption effects with high fidelity. This problem is particularly acute when data multiplicity is low. This paper presents an analytical absorption correction strategy (implemented in new software AnACor) based on a volumetric model of the sample derived from X-ray tomography. Individual path lengths through the different sample materials for all reflections are determined by a ray-tracing method. Several approaches for absorption corrections (spherical harmonics correction, analytical absorption correction and a combination of the two) are compared for two samples, the membrane protein OmpK36 GD, measured at a wavelength of λ = 3.54 Å, and chlorite dismutase, measured at λ = 4.13 Å. Data set statistics, the peak heights in the anomalous difference Fourier maps and the success of experimental phasing are used to compare the results from the different absorption correction approaches. The strategies using the new analytical absorption correction are shown to be superior to the standard spherical harmonics corrections. While the improvements are modest in the 3.54 Å data, the analytical absorption correction outperforms spherical harmonics in the longer-wavelength data (λ = 4.13 Å), which is also reflected in the reduced amount of data being required for successful experimental phasing.
|
Jun 2024
|
|
B23-Circular Dichroism
I24-Microfocus Macromolecular Crystallography
|
Ryan M.
Lithgo
,
Marko
Hanževački
,
Gemma
Harris
,
Jos J. A. G.
Kamps
,
Ellie
Holden
,
Tiberiu-Marius
Gianga
,
Justin L. P.
Benesch
,
Christof M.
Jäger
,
Anna K.
Croft
,
Rohanah
Hussain
,
Jon L.
Hobman
,
Allen M.
Orville
,
Andrew
Quigley
,
Stephen B.
Carr
,
David J.
Scott
Open Access
Abstract: The periplasmic chaperone SilF has been identified as part of an Ag(I) detoxification system in Gram negative bacteria. Sil proteins also bind Cu(I), but with reported weaker affinity, therefore leading to the designation of a specific detoxification system for Ag(I). Using isothermal titration calorimetry we show that binding of both ions is not only tighter than previously thought, but of very similar affinities. We investigated the structural origins of ion binding using molecular dynamics and QM/MM simulations underpinned by structural and biophysical experiments. The results of this analysis showed that the binding site adapts to accommodate either ion, with key interactions with the solvent in the case of Cu(I). The implications of this are that Gram negative bacteria do not appear to have evolved a specific Ag(I) efflux system but take advantage of the existing Cu(I) detoxification system. Therefore, there are consequences for how we define a particular metal resistance mechanism and understand its evolution in the environment.
|
Oct 2023
|
|
|
|
Open Access
Abstract: The two SARS-CoV-2 proteases, i.e. the main protease (M pro ) and the papain-like protease (PL pro ), which hydrolyze the viral polypeptide chain giving functional non-structural proteins, are essential for viral replication and are medicinal chemistry targets. We report a high-throughput mass spectrometry (MS)-based assay which directly monitors PL pro catalysis in vitro . The assay was applied to investigate the effect of reported small-molecule PL pro inhibitors and selected M pro inhibitors on PL pro catalysis. The results reveal that some, but not all, PL pro inhibitor potencies differ substantially from those obtained using fluorescence-based assays. Some substrate-competing M pro inhibitors, notably PF-07321332 (nirmatrelvir) which is in clinical development, do not inhibit PL pro . Less selective M pro inhibitors, e.g. auranofin, inhibit PL pro , highlighting the potential for dual PL pro /M pro inhibition. MS-based PL pro assays, which are orthogonal to widely employed fluorescence-based assays, are of utility in validating inhibitor potencies, especially for inhibitors operating by non-covalent mechanisms.
|
Jan 2022
|
|
I03-Macromolecular Crystallography
I04-1-Macromolecular Crystallography (fixed wavelength)
I04-Macromolecular Crystallography
I24-Microfocus Macromolecular Crystallography
|
Patrick
Rabe
,
Jos J. A. G.
Kamps
,
Kyle D.
Sutherlin
,
James D. S.
Linyard
,
Pierre
Aller
,
Cindy C.
Pham
,
Mikako
Makita
,
Ian
Clifton
,
Michael A.
Mcdonough
,
Thomas M.
Leissing
,
Denis
Shutin
,
Pauline A.
Lang
,
Agata
Butryn
,
Jurgen
Brem
,
Sheraz
Gul
,
Franklin D.
Fuller
,
In-Sik
Kim
,
Mun Hon
Cheah
,
Thomas
Fransson
,
Asmit
Bhowmick
,
Iris D.
Young
,
Lee
O'Riordan
,
Aaron S.
Brewster
,
Ilaria
Pettinati
,
Margaret
Doyle
,
Yasumasa
Joti
,
Shigeki
Owada
,
Kensuke
Tono
,
Alexander
Batyuk
,
Mark S.
Hunter
,
Roberto
Alonso-Mori
,
Uwe
Bergmann
,
Robin L.
Owen
,
Nicholas K.
Sauter
,
Timothy D. W.
Claridge
,
Carol V.
Robinson
,
Vittal K.
Yachandra
,
Junko
Yano
,
Jan F.
Kern
,
Allen M.
Orville
,
Christopher J.
Schofield
Diamond Proposal Number(s):
[23459, 19458]
Open Access
Abstract: Isopenicillin N synthase (IPNS) catalyzes the unique reaction of L-δ-(α-aminoadipoyl)-L-cysteinyl-D-valine (ACV) with dioxygen giving isopenicillin N (IPN), the precursor of all natural penicillins and cephalosporins. X-ray free-electron laser studies including time-resolved crystallography and emission spectroscopy reveal how reaction of IPNS:Fe(II):ACV with dioxygen to yield an Fe(III) superoxide causes differences in active site volume and unexpected conformational changes that propagate to structurally remote regions. Combined with solution studies, the results reveal the importance of protein dynamics in regulating intermediate conformations during conversion of ACV to IPN. The results have implications for catalysis by multiple IPNS-related oxygenases, including those involved in the human hypoxic response, and highlight the power of serial femtosecond crystallography to provide insight into long-range enzyme dynamics during reactions presently impossible for nonprotein catalysts.
|
Aug 2021
|
|
I24-Microfocus Macromolecular Crystallography
|
Agata
Butryn
,
Philipp S.
Simon
,
Pierre
Aller
,
Philip
Hinchliffe
,
Ramzi N.
Massad
,
Gabriel
Leen
,
Catherine L.
Tooke
,
Isabel
Bogacz
,
In-Sik
Kim
,
Asmit
Bhowmick
,
Aaron S.
Brewster
,
Nicholas E.
Devenish
,
Jurgen
Brem
,
Jos J. A. G.
Kamps
,
Pauline A.
Lang
,
Patrick
Rabe
,
Danny
Axford
,
John H.
Beale
,
Bradley
Davy
,
Ali
Ebrahim
,
Julien
Orlans
,
Selina L. S.
Storm
,
Tiankun
Zhou
,
Shigeki
Owada
,
Rie
Tanaka
,
Kensuke
Tono
,
Gwyndaf
Evans
,
Robin L.
Owen
,
Frances A.
Houle
,
Nicholas K.
Sauter
,
Christopher J.
Schofield
,
James
Spencer
,
Vittal K.
Yachandra
,
Junko
Yano
,
Jan F.
Kern
,
Allen M.
Orville
Diamond Proposal Number(s):
[19458, 25260]
Open Access
Abstract: Serial femtosecond crystallography has opened up many new opportunities in structural biology. In recent years, several approaches employing light-inducible systems have emerged to enable time-resolved experiments that reveal protein dynamics at high atomic and temporal resolutions. However, very few enzymes are light-dependent, whereas macromolecules requiring ligand diffusion into an active site are ubiquitous. In this work we present a drop-on-drop sample delivery system that enables the study of enzyme-catalyzed reactions in microcrystal slurries. The system delivers ligand solutions in bursts of multiple picoliter-sized drops on top of a larger crystal-containing drop inducing turbulent mixing and transports the mixture to the X-ray interaction region with temporal resolution. We demonstrate mixing using fluorescent dyes, numerical simulations and time-resolved serial femtosecond crystallography, which show rapid ligand diffusion through microdroplets. The drop-on-drop method has the potential to be widely applicable to serial crystallography studies, particularly of enzyme reactions with small molecule substrates.
|
Jul 2021
|
|
I04-Macromolecular Crystallography
I24-Microfocus Macromolecular Crystallography
|
Alen
Krajnc
,
Jurgen
Brem
,
Philip
Hinchliffe
,
Karina
Calvopina
,
Tharindi
Panduwawala
,
Pauline A.
Lang
,
Jos J. A. G.
Kamps
,
Jonathan M.
Tyrell
,
Emma
Widlake
,
Benjamin G.
Saward
,
Timothy R.
Walsh
,
James
Spencer
,
Christopher J.
Schofield
Diamond Proposal Number(s):
[17212, 18069]
Open Access
Abstract: The bicyclic boronate VNRX-5133 is a new type of β-lactamase inhibitor in clinical development. We report that VNRX-5133 inhibits serine-β-lactamases (SBLs) and some clinically important metallo-β-lactamases (MBLs), including NDM-1 and VIM-1/2. VNRX-5133 activity against IMP-1 and tested B2/B3 MBLs was lower/not observed. Crystallography reveals how VNRX-5133 binds to the class D SBL OXA-10 and NDM-1. The crystallographic results highlight the ability of bicyclic boronates to inhibit SBLs and MBLs via binding of a tetrahedral (sp3) boron species. The structures imply conserved binding of the bicyclic core with SBLs/MBLs. With NDM-1, by crystallography we observed an unanticipated VNRX-5133 binding mode involving cyclization of its acylamino oxygen onto the boron of the bicyclic core. Different side-chain-dependent binding modes for bicyclic boronates imply scope for optimisation. The results further support the ‘high energy intermediate’ analogue approach for broad-spectrum β-lactamase inhibitor development and highlight the ability of boron-inhibitors to interchange between different hybridization states / binding modes.
|
Aug 2019
|
|