Detectors
|
N.
Goyal
,
F. J.
Iguaz
,
S.
Aplin
,
A.
Balerna
,
P.
Bell
,
J.
Casas
,
M.
Cascella
,
S.
Chatterji
,
C.
Cohen
,
E.
Collet
,
E N.
Gimenez
,
H.
Graafsma
,
H.
Hirsemann
,
K.
Klementiev
,
T.
Kolodziej
,
T.
Martin
,
Ralf H.
Menk
,
C.
Menneglier
,
C.
Meraihia
,
J. R.
Murias
,
M.
Porro
,
M.
Quispe
,
B.
Schmitt
,
S.
Scully
,
M.
Turcato
,
C.
Ward
,
E.
Welter
Open Access
Abstract: The first operational prototype of a high-purity germanium (HPGe) detector developed within the European LEAPS-INNOV project is presented in this work. This prototype features a monolithic, multi-element sensor optimized for high-resolution X-ray spectroscopy in the hard X-ray regime, intended for handing high count rates of 30 Mcps, across a broad energy range (5–100 keV). The present prototype demonstrates a throughput of about 150–200 kcps/pixel, corresponding to a total count rate of about 1.5–2 Mcps for the full 10 element detector. We discuss here a complete laboratory-based characterization of the detector’s performance, as well as an on-beam evaluation at the BM05 beamline of the ESRF synchrotron facility, using monochromatic X-rays in the 20–50 keV energy range. We provide a detailed performance assessment that also includes a phenomenological defect-depth estimation model.
|
Dec 2026
|
|
Detectors
|
C. B.
Wunderer
,
M.
Hajheidari
,
A.
Marras
,
Th.
Wendt
,
F.
Anders
,
J.
Correa
,
M.
Dahlgruen
,
J.
Gebert
,
T.
Hirono
,
H.
Hirsemann
,
F.
Krivan
,
S.
Lange
,
S. Y.
Rah
,
I.
Shevyakov
,
V.
Vardanyan
,
M.
Hoesch
,
K.
Bagschik
,
N.
Guerrini
,
B.
Marsh
,
I.
Sedgwick
,
G.
Cautero
,
D.
Giuressi
,
R.
Menk
,
L.
Stebel
,
A.
Greer
,
T.
Nicholls
,
W.
Nichols
,
M.
Nakhostin
,
H. J.
Hyun
,
K. S.
Kim
,
S. H.
Kim
,
S. Y.
Park
,
F. J.
Iguaz
,
H.
Graafsma
Open Access
Abstract: PERCIVAL, “pixellated energy-resolving CMOS imager versatile and large”, is a 2-megapixel soft X-ray imager developed for use at FELs and modern-day synchrotrons. A combination of capabilities is necessary to meet the scientific needs: a large, uninterrupted imaging area with small pixels, high dynamic range, high frame rate, and soft X-ray suitable entrance window to the sensor. A single PERCIVAL sensor offers over 4 cm × 4 cm uninterrupted imaging area (1408 × 1484 pixels of 27 × 27 μm2). Three auto-adapting gains (per pixel per image) provide the large dynamic range from 13 e- noise to over 3 Me- signal. The sensor is designed for up to 300 Hz frame rate, and can be operated faster in ROI mode. The first generation of the sensor was hampered by severe crosstalk preventing parallel operation of ADC, streamout, and pixel switches and by non-uniformity of baselines over the sensor. A revised “respin” sensor addresses these issues at the root — and good noise performance at higher frame rates as well as a more uniform baseline can now be provided to users. The first generation DAQ system — still based on existing Virtex5 hardware — had limitations that ultimately prevented handling the fast data rates from a Percival running at full speed, or other complexities such as ROI operation. A complete overhaul of the percival-specific DAQ components (FPGA with periphery and firmware) today enables acquisition at envisioned frame rates and in ROI mode. This paper summarizes first laboratory results from the respin sensors in combination with the new DAQ hardware and firmware.
|
Jan 2026
|
|
Detectors
|
L.
Manzanillas
,
S.
Aplin
,
A.
Balerna
,
P.
Bell
,
J.
Casas
,
M.
Cascella
,
S.
Chatterji
,
C.
Cohen
,
G.
Dennis
,
P.
Fajardo
,
H.
Graafsma
,
H.
Hirsemann
,
F. J.
Iguaz
,
K.
Klementiev
,
T.
Kołodziej
,
T.
Martin
,
R.
Menk
,
F.
Orsini
,
M.
Porro
,
M.
Quispe
,
B.
Schmitt
,
N.
Tartoni
,
M.
Turcato
,
C.
Ward
,
E.
Welter
Abstract: In past years efforts have concentrated on the development of arrays of Silicon Drift Detectors for X-ray spectroscopy. This is in stark contrast to the little effort that has been devoted to the improvement of germanium detectors, in particular for synchrotron applications. Germanium detectors have better energy resolution and are more efficient in detecting high energy photons than silicon detectors. In this context, the detector consortium of the European project LEAPS-INNOV has set an ambitious R&D program devoted to the development of a new generation of multi-element monolithic germanium detectors for X-ray detection. In order to improve the performance of the detector under development, simulations of the different detector design options have been performed. In this contribution, the efforts in terms of R&D are outlined with a focus on the modelization of the detector geometry and first performance results. These performance results show that a signal-to-background ratio larger than 1000 can be achieved in the energy range of interest from 5 keV to 100 keV.
|
Dec 2022
|
|
Detectors
|
F.
Orsini
,
S.
Aplin
,
A.
Balerna
,
P.
Bell
,
J.
Casas
,
M.
Cascella
,
S.
Chatterji
,
C.
Cohen
,
G.
Dennis
,
P.
Fajardo
,
H.
Graafsma
,
H.
Hirsemann
,
F. J.
Iguaz
,
K.
Klementiev
,
T.
Kołodziej
,
L.
Manzanillas
,
T.
Martin
,
R.
Menk
,
M.
Porro
,
M.
Quispe
,
B.
Schmitt
,
N.
Tartoni
,
M.
Turcato
,
C.
Ward
,
E.
Welter
Abstract: The high brilliance and coherent beams resulting from recent upgraded synchrotron radiation facilities open the way for a large range of experiments, where detectors play a key role in the techniques and methods developed to fully exploit the upgraded synchrotron. For instance, one of the major limitations of XAFS experiment is the performance of the detectors. In order to be able to measure more challenging samples and to cope with the very high photon flux of the current and future (diffraction limited) sources, technological developments of detectors are necessary. In this framework, the germanium detector developed in the European project LEAPS-INNOV aims at improving several technological aspects. This type of detector represents a very important class of instruments for X-ray spectroscopy due to the fact that they enable to detect efficiently photons of considerable higher energy with respect to silicon detectors. The objective of this project consists in pushing the detector performance beyond the state-of-the-art. Preliminary layout and main choices for the design studies of this new detector are presented in this paper.
|
Oct 2022
|
|
I13-1-Coherence
|
Diamond Proposal Number(s):
[4998]
Open Access
Abstract: Dispersions of colloidal platelets in the nematic phase display strong wall anchoring, which competes with the reorientational motion of the director when the system is subjected to flow. We show that the mechanical response to large amplitude oscillatory strain and stress depends on the confinement of the system due to this competition. We elucidate the underlying structural response by deflecting a x-ray beam vertically along the vorticity direction of a Couette geometry, such that the structure can be probed throughout the gap with an unprecedented spatial resolution while recording in situ the mechanical response. We observe strong inhomogeneities in terms of the orientation of the nematic director, depending on the extent of the system's yield during an oscillation. At small strain amplitudes, we observe a small region where the director oscillates between wall anchoring and the Leslie angle, while in the bulk, the director tilts out of the flow–flow gradient plane. At large strain amplitudes, the oscillations of the director are symmetric, close to the wall, and propagate into the bulk. Here, a twinning is observed where the director rotates out-of-plane in two opposite directions. Using the sequence of physical process method to analyze the LAOStrain response for both the mechanical and structural response, we locate the yielding in a small time-window around flow reversal and identify that the bulk is the main contributor to the mechanical response. The structural response to LAOStress is much less pronounced even when the stress amplitude causes significant shear thinning.
|
Dec 2021
|
|
Detectors
|
J.
Correa
,
A.
Marras
,
C. B.
Wunderer
,
P.
Göttlicher
,
S.
Lange
,
S.
Reza
,
I.
Shevyakov
,
M.
Tennert
,
M.
Niemann
,
H.
Hirsemann
,
S.
Smoljanin
,
J.
Supra
,
Q.
Xia
,
M.
Zimmer
,
A.
Allahgoli
,
A.
Gloskovskii
,
J.
Viefhaus
,
F.
Scholz
,
J.
Seltmann
,
S.
Klumpp
,
G.
Cautero
,
D.
Giuressi
,
A.
Khromova
,
R.
Menk
,
G.
Pinaroli
,
L.
Stebel
,
S.
Rinaldi
,
N.
Zema
,
D.
Catone
,
U.
Pedersen
,
N.
Tartoni
,
N.
Guerrini
,
B.
Marsh
,
I.
Sedgwick
,
T. J.
Nicholls
,
R.
Turchetta
,
H. J.
Hyun
,
K. S.
Kim
,
S. Y.
Rah
,
M. E.
Hoenk
,
A. D.
Jewell
,
T. J.
Jones
,
S.
Nikzad
,
H.
Graafsma
Abstract: The PERCIVAL soft X-ray imager is being developed by DESY, RAL, Elettra, DLS, and PAL to address the challenges at high brilliance Light Sources such as new-generation Synchrotrons and Free Electron Lasers. Typical requirements for detector systems at these sources are high frame rates, large dynamic range, single-photon counting capability with low probability of false positives, high quantum efficiency, and (multi)-mega-pixel arrangements. PERCIVAL is a monolithic active pixel sensor, based on CMOS technology. It is designed for the soft X-ray regime and, therefore, it is post-processed in order to achieve high quantum efficiency in its primary energy range (250 eV to 1 keV) . This work will report on the latest experimental results on charge collection efficiency obtained for multiple back-side-illuminated test sensors during two campaigns, at the P04 beam-line at PETRA III, and the CiPo beam-line at Elettra, spanning most of the primary energy range as well as testing the performance for photon-energies below 250 eV . In addition, XPS surface analysis was used to cross-check the obtained results.
|
Dec 2016
|
|
Detectors
|
A.
Khromova
,
G.
Cautero
,
D.
Giuressi
,
R.
Menk
,
G.
Pinaroli
,
L.
Stebel
,
J.
Correa
,
A.
Marras
,
C. B.
Wunderer
,
S.
Lange
,
M.
Tennert
,
M.
Niemann
,
H.
Hirsemann
,
S.
Smoljanin
,
S.
Reza
,
H.
Graafsma
,
P.
Göttlicher
,
I.
Shevyakov
,
J.
Supra
,
Q.
Xia
,
M.
Zimmer
,
N.
Guerrini
,
B.
Marsh
,
I.
Sedgwick
,
T.
Nicholls
,
R.
Turchetta
,
U.
Pedersen
,
N.
Tartoni
,
H. J.
Hyun
,
K. S.
Kim
,
S. Y.
Rah
,
M. E.
Hoenk
,
A. D.
Jewell
,
T. J.
Jones
,
S.
Nikzad
Abstract: The PERCIVAL (Pixelated Energy Resolving CMOS Imager, Versatile And Large) soft X-ray 2D imaging detector is based on stitched, wafer-scale sensors possessing a thick epi-layer, which together with back-thinning and back-side illumination yields elevated quantum efficiency in the photon energy range of 125–1000 eV. Main application fields of PERCIVAL are foreseen in photon science with FELs and synchrotron radiation. This requires high dynamic range up to 105 ph @ 250 eV paired with single photon sensitivity with high confidence at moderate frame rates in the range of 10–120 Hz. These figures imply the availability of dynamic gain switching on a pixel-by-pixel basis and a highly parallel, low noise analog and digital readout, which has been realized in the PERCIVAL sensor layout. Different aspects of the detector performance have been assessed using prototype sensors with different pixel and ADC types. This work will report on the recent test results performed on the newest chip prototypes with the improved pixel and ADC architecture. For the target frame rates in the 10–120 Hz range an average noise floor of 14e− has been determined, indicating the ability of detecting single photons with energies above 250 eV. Owing to the successfully implemented adaptive 3-stage multiple-gain switching, the integrated charge level exceeds 4 centerdot 106 e− or 57000 X-ray photons at 250 eV per frame at 120 Hz. For all gains the noise level remains below the Poisson limit also in high-flux conditions. Additionally, a short overview over the updates on an oncoming 2 Mpixel (P2M) detector system (expected at the end of 2016) will be reported.
|
Nov 2016
|
|
I13-1-Coherence
|
Abstract: Structural distortion and relaxation are central to any liquid flow. Their full understanding requires simultaneous probing of the mechanical as well as structural and dynamical response. We provide the first full dynamical measurement of the transient structure using combined coherent X-ray scattering and rheology on electrostatically interacting colloidal fluids. We find a stress overshoot during the start-up of shear which is due to the strong anisotropic overstretching and compression of nearest-neighbor distances. The rheological response is reflected in uncorrelated entropy-driven intensity fluctuations. While the structural distortion under steady shear is well described by Smoluchowski theory, we find an increase of the particle dynamics beyond the trivial contribution of flow. After the cessation of shear, the full fluid microstructure and dynamics are restored, both on the structural relaxation timescale. We thus find unique structure-dynamics relations in liquid flow, responsible for the macroscopic rheological behavior of the system.
|
Oct 2015
|
|