I13-2-Diamond Manchester Imaging
|
Diamond Proposal Number(s):
[19322]
Abstract: In-line phase contrast synchrotron tomography combined with in situ mechanical loading enables the characterisation of soft tissue micromechanics via digital volume correlation (DVC) within whole organs. Optimising scan time is important for reducing radiation dose from multiple scans and to limit sample movement during acquisition. Also, although contrasted edges provided by in-line phase contrast tomography of soft tissues are useful for DVC, the effect of phase contrast imaging on its accuracy has yet to be investigated. Due to limited time at synchrotron facilities, scan parameters are often decided during imaging and their effect on DVC accuracy is not fully understood. Here, we used previously published data of intervertebral disc phase contrast tomography to evaluate the influence of i) fibrous image texture, ii) number of projections, iii) tomographic reconstruction method, and iv) phase contrast propagation distance on DVC results. A greater understanding of how image texture influences optimal DVC tracking was obtained by visualising objective function mapping, enabling tracking inaccuracies to be identified. When reducing the number of projections, DVC was minimally affected by image high frequency noise but with a compromise in accuracy. Iterative reconstruction methods improved image signal-to-noise and consequently significantly lowered DVC displacement uncertainty. Propagation distance was shown to affect DVC accuracy. Consistent DVC results were achieved within a propagation distance range which provided contrast to the smallest scale features, where; too short a distance provided insufficient features to track, whereas too long led to edge effect inconsistencies, particularly at greater deformations. Although limited to a single sample type and image setup, this study provides general guidelines for future investigations when optimising image quality and scan times for in situ phase contrast x-ray tomography of fibrous connective tissues.
|
Nov 2022
|
|
I22-Small angle scattering & Diffraction
|
Diamond Proposal Number(s):
[17664, 13337]
Open Access
Abstract: Measurement of the properties of bone as a material can happen in various length scales in its hierarchical and composite structure. The aim of this study was to test the tissue level properties of clinically-relevant human bone samples which were collected from donors belonging to three groups: ageing donors who suffered no fractures (Control); untreated fracture patients (Fx-Untreated) and patient who experienced hip fracture despite being treated with bisphosphonates (Fx-BisTreated). Tissue level properties were assessed by (a) nanoindentation and (b) synchrotron tensile tests (STT) where strains were measured at the ‘tissue’, ‘fibril’ and ‘mineral’ levels by using simultaneous Wide-angle - (WAXD) and Small angle- X-ray diffraction (SAXD). The composition was analysed by thermogravimetric analysis and material level endo- and exo-thermic reactions by differential scanning calorimetry (TGA/DSC3+). Irrespective of treatment fracture donors exhibited significantly lower tissue, fibril and mineral strain at the micro and nanoscale respectively and had a higher mineral content than controls. In nanoindentation only nanohardness was significantly greater for Controls and Fx-BisTreated versus Fx-Untreated. The other nanoindentation parameters did not vary significantly across the three groups. There was a highly significant positive correlation (p < 0.001) between organic content and tissue level strain behaviour. Overall hip-fractures were associated with lower STT nanostrains and it was behaviour measured by STT which proved to be a more effective approach for predicting fracture risk because evidently it was able to demonstrate the mechanical deficit for the bone tissue of the donors who had experienced fractures.
|
Nov 2022
|
|
I13-2-Diamond Manchester Imaging
|
Diamond Proposal Number(s):
[10315, 16497, 22575]
Open Access
Abstract: Musculoskeletal tissues are complex hierarchical materials where mechanical response is linked to structural and material properties at different dimensional levels. Therefore, high-resolution three-dimensional tomography is very useful for assessing tissue properties at different scales. In particular, Synchrotron Radiation micro-Computed Tomography (SR-microCT) has been used in several applications to analyze the structure of bone and biomaterials. In the past decade the development of digital volume correlation (DVC) algorithms applied to SR-microCT images and its combination with in situ mechanical testing (four-dimensional imaging) have allowed researchers to visualise, for the first time, the deformation of bone tissue and its interaction with biomaterials under different loading scenarios. However, there are several experimental challenges that make these measurements difficult and at high risk of failure. Challenges relate to sample preparation, imaging parameters, loading setup, accumulated tissue damage for multiple tomographic acquisitions, reconstruction methods and data processing. Considering that access to SR-microCT facilities is usually associated with bidding processes and long waiting times, the failure of these experiments could notably slow down the advancement of this research area and reduce its impact. Many of the experimental failures can be avoided with increased experience in performing the tests and better guidelines for preparation and execution of these complex experiments; publication of negative results could help interested researchers to avoid recurring mistakes. Therefore, the goal of this article is to highlight the potential and pitfalls in the design and execution of in situ SR-microCT experiments, involving multiple scans, of musculoskeletal tissues for the assessment of their structural and/or mechanical properties. The advice and guidelines that follow should improve the success rate of this type of experiment, allowing the community to reach higher impact more efficiently.
|
May 2022
|
|
I13-2-Diamond Manchester Imaging
|
Diamond Proposal Number(s):
[22575]
Abstract: Machine learning methods have the potential to transform imaging techniques and analysis for healthcare applications with automation, making diagnostics and treatment more accurate and efficient, as well as to provide mechanistic insights into tissue deformation and fracture in physiological and pathological conditions. Here we report an exploratory investigation for the classification and prediction of mechanical states of cortical and trabecular bone tissue using convolutional neural networks (CNNs), residual neural networks (ResNet), and transfer learning applied to a novel dataset derived from high-resolution synchrotron-radiation micro-computed tomography (SR-microCT) images acquired in uniaxial continuous compression in situ. We present the systematic optimization of CNN architectures for classification of this dataset, visualization of class-defining features detected by the CNNs using gradient class activation maps (Grad-CAMs), comparison of CNN performance with ResNet and transfer learning models, and perhaps most critically, the challenges that arose from applying machine learning methods to an experimentally-derived dataset for the first time. With optimized CNN architectures, we obtained trained models that classified novel images between failed and pristine classes with over 98% accuracy for cortical bone and over 90% accuracy for trabecular bone. Harnessing a pre-trained ResNet with transfer learning, we further achieved over 98% accuracy on the cortical dataset, and 99% on the trabecular dataset. This demonstrates that powerful classifiers for high-resolution SR-microCT images can be developed even with few unique training samples and invites further development through the inclusion of more data and training methods to move towards novel, fundamental, and machine learning-driven insights into microstructural states and properties of bone.
|
Aug 2021
|
|
I12-JEEP: Joint Engineering, Environmental and Processing
|
Diamond Proposal Number(s):
[11204]
Abstract: The fracture resistance of load-bearing trabecular bone is adversely affected by diseases such as osteoporosis. However, there are few published measurements of trabecular bone fracture toughness due to the difficulty of conducting reliable tests in small specimens of this highly porous material. A new approach is demonstrated that uses digital volume correlation of X-ray computed tomographs to measure 3D displacement fields in which the crack shape and size can be objectively identified using a phase congruency analysis. The criteria for crack propagation, i.e. fracture toughness, can then be derived by finite element simulation, with knowledge of the elastic properties.
|
Sep 2020
|
|
I13-2-Diamond Manchester Imaging
|
Diamond Proposal Number(s):
[14080]
Abstract: The use of synchrotron radiation micro-computed tomography (SR-microCT) is becoming increasingly popular for studying the relationship between microstructure and bone mechanics subjected to in situ mechanical testing. However, it is well known that the effect of SR X-ray radiation can considerably alter the mechanical properties of bone tissue. Digital volume correlation (DVC) has been extensively used to compute full-field strain distributions in bone specimens subjected to step-wise mechanical loading, but tissue damage from sequential SR-microCT scans has not been previously addressed. Therefore, the aim of this study is to examine the influence of SR irradiation-induced microdamage on the apparent elastic properties of trabecular bone using DVC applied to in situ SR-microCT tomograms obtained with different exposure times. Results showed how DVC was able to identify high local strain levels (>10,000 µε) corresponding to visible microcracks at high irradiation doses (~230 kGy), despite the apparent elastic properties remained unaltered. Microcracks were not detected and bone plasticity was preserved for low irradiation doses (~33 kGy), although image quality and consequently, DVC performance were reduced. DVC results suggested some local deterioration of tissue that might have resulted from mechanical strain concentration further enhanced by some level of local irradiation even for low accumulated dose.
|
Aug 2018
|
|
I22-Small angle scattering & Diffraction
|
Diamond Proposal Number(s):
[12528]
Open Access
Abstract: Peripheral nerves are continuously subjected to mechanical forces, both during everyday movement and as a result of traumatic events. Current mechanical models focus on explaining the macroscopic behaviour of the tissue, but do not investigate how tissue strain translates to deformations at the microstructural level. Predicting the effect of macro-scale loading can help explain changes in nerve function and suggest new strategies for prevention and therapy.
The aim of this study was to determine the relationship between macroscopic tensile loading and micro scale deformation in structures thought to be mechanically active in peripheral nerves: the myelin sheath enveloping axons, and axially aligned epineurial collagen fibrils. The microstructure was probed using x-ray diffraction during in situ tensile loading, measuring the micro-scale deformation in collagen and myelin, combined with high definition macroscopic video extensiometry.
At a tissue level, tensile loading elongates nerves axially, whilst simultaneously compressing circumferentially. The non-linear behaviour observed in both directions is evidence, circumferentially, that the nerve core components have the ability to rearrange before bearing load and axially, of a recruitment process in epineurial collagen. At the molecular level, axially aligned epineurial collagen fibrils are strained, whilst the myelin sheath enveloping axons is compressed circumferentially. During induced compression, the myelin sheath shows high circumferential stiffness, indicating a possible role in mechanical protection of axons. The myelin sheath is deformed from low loads, despite the non-linearity of whole tissue compression, indicating more than one mechanism contributing to myelin compression. Epineurial collagen shows similar load-bearing characteristics to those of other collagenous connective tissues.
This new microstructural knowledge is key to understand peripheral nerve mechanical behaviour, and will support new regenerative strategies for traumatic and repetitive injury.
|
Jul 2018
|
|
I02-Macromolecular Crystallography
|
Diamond Proposal Number(s):
[919]
Open Access
Abstract: A numerical model based on continuum mechanics theory has been developed which represents the 3D anisotropic behaviour of the corneal stroma. Experimental data has been gathered from a number of previous studies to provide the basis and calibration parameters for the numerical modelling. The resulting model introduces numerical representation of collagen fibril density and its related regional variation, interlamellar cohesion and age-related stiffening in an anisotropic model of the human cornea. Further, the model incorporates previous modelling developments including representation of lamellae anisotropy and stiffness of the underlying matrix. Wide angle X-ray scattering has provided measured data which quantifies relative fibril anisotropy in the 2D domain. Accurate numerical description of material response to deformation is essential to providing representative simulations of corneal behaviour. Representing experimentally obtained 2D anisotropy and regional density variation in the 3D domain is an essential component of this accuracy. The constitutive model was incorporated into finite element analysis. Combining with inverse analysis, the model was calibrated to an extensive experimental database of ex vivo corneal inflation tests and ex vivo corneal shear tests. This model represents stiffness of the underlying matrix which is 23 orders of magnitude than the mechanical response representing the collagen fibrils in the lamellae. The presented model, along with its age dependent material coefficients, allows finite element modelling for an individual patient with material stiffness approximated based on their age. This has great potential to be used in both daily clinical practice for the planning and optimisation of corrective procedures and in pre-clinical optimisation of diagnostic procedures.
|
Feb 2015
|
|
I22-Small angle scattering & Diffraction
|
Diamond Proposal Number(s):
[8555]
Abstract: The material properties of ligaments are not well characterized at rates of deformation that occur during high-speed injuries. The aim of this study was to measure the material properties of lateral collateral ligament of the porcine stifle joint in a uniaxial tension model through strain rates in the range from 0.01 to 100/s. Failure strain, tensile modulus and failure stress were calculated. Across the range of strain rates, tensile modulus increased from 288 to 905 MPa and failure stress increased from 39.9 to 77.3 MPa. The strain-rate sensitivity of the material properties decreased as deformation rates increased, and reached a limit at approximately 1/s, beyond which there was no further significant change. In addition, time resolved microfocus small angle X-ray scattering was used to measure the effective fibril modulus (stress/fibril strain) and fibril to tissue strain ratio. The nanoscale data suggest that the contribution of the collagen fibrils towards the observed tissue-level deformation of ligaments diminishes as the loading rate increases. These findings help to predict the patterns of limb injuries that occur at different speeds and improve computational models used to assess and develop mitigation technology.
|
Jan 2015
|
|
I22-Small angle scattering & Diffraction
|
Open Access
Abstract: The knowledge of the mechanical properties of dental materials related to their hierarchical structure is essential for understanding and predicting the effect of microstructural alterations on the performance of dental tissues in the context of forensic and archaeological investigation as well as laser irradiation treatment of caries. So far, few studies have focused on the nano-scale structure-mechanical function relations of human teeth altered by chemical or thermal treatment. The response of dental tissues to thermal treatment is thought to be strongly affected by the mineral crystallite size, their spatial arrangement and preferred orientation. In this study, synchrotron-based small and wide angle X-ray scattering (SAXS/WAXS) techniques were used to investigate the micro-structural alterations (mean crystalline thickness, crystal perfection and degree of alignment) of heat-affected dentine and enamel in human dental teeth. Additionally, nanoindentation mapping was applied to detect the spatial and temperature-dependent nano-mechanical properties variation. The SAXS/WAXS results revealed that the mean crystalline thickness distribution in dentine was more uniform compared with that in enamel. Although in general the mean crystalline thickness increased both in dentine and enamel as the temperature increased, the local structural variations gradually reduced. Meanwhile, the hardness and reduced modulus in enamel decreased as the temperature increased, while for dentine, the tendency reversed at high temperature. The analysis of the correlation between the ultrastructure and mechanical properties coupled with the effect of temperature demonstrates the effect of mean thickness and orientation on the local variation of mechanical property. This structural–mechanical property alteration is likely to be due to changes of HAp crystallites, thus dentine and enamel exhibit different responses at different temperatures. Our results enable an improved understanding of the mechanical properties correlation in hierarchical biological materials, and human dental tissue in particular.
|
Dec 2013
|
|