Publication
Article Metrics
Citations
Online attention
Harmonic cavity design choice for lifetime increase in Diamond-II
DOI:
10.18429/JACoW-IPAC2019-TUPGW078
Authors:
Teresia
Olsson
(Diamond Light Source)
,
R.
Bartolini
(Diamond Light Source)
,
I. P. S.
Martin
(Diamond Light Source)
Co-authored by industrial partner:
No
Type:
Conference Paper
Conference:
IPAC2019
Peer Reviewed:
No
State:
Published (Approved)
Published:
June 2019

Abstract: The ongoing trend towards synchrotron light storage rings with ultralow emittance leads to a requirement for strong magnet gradients, which reduce the dynamic aperture and thus the Touschek lifetime of the machine. This is also the case for the planned upgrade of the Diamond Light Source. One option to increase the Touschek lifetime is to lengthen the electron bunches with a harmonic cavity operated close to a harmonic of the fundamental RF frequency. This paper presents studies of a harmonic cavity for Diamond-II with the focus on maximising the lifetime increase. It is foreseen that the ring will have to operate with a gap in the fill pattern to avoid instabilities and therefore multiparticle tracking was used to determine the effect on stability and lifetime for various cavity parameters taking into account transient beam loading.
Subject Areas:
Engineering
Technical Areas:
Electrical Engineering
Added On:
13/08/2019 14:57
Documents:
tupgw078.pdf
Discipline Tags:
Engineering & Technology
Technical Tags: