Publication

Article Metrics

Citations


Online attention

Bunch purity measurement for Diamond

DOI: 10.1016/j.nima.2006.07.059 DOI Help

Authors: C. A. Thomas (Diamond Light Source) , G. Rehm (Diamond Light Source) , H. L. Owen (CCLRC Daresbury Laboratory) , N. G. Wyles (CCLRC Daresbury Laboratory) , S. W. Botchway (Central Laser Facility, RAL) , V. Schlott (Swiss Light Source) , M. Wahl (PicoQuant GmbH)
Co-authored by industrial partner: No

Type: Journal Paper
Journal: Nuclear Instruments & Methods In Physics Research Section A-accelerators Spectrometers Detectors And Associated Equipment , VOL 566 (2) , PAGES 762-766

State: Published (Approved)
Published: August 2006

Abstract: Measurement of the fill pattern of synchrotron storage rings is important for several reasons, including checking the quality of the injection system and the generation of special fill patterns for time-resolved experiments. For the new national X-ray facility based on the Diamond 3 GeV electron storage ring, it is planned to measure the beam quality in a short time of several minutes by using a time-correlated single photon counting method. The method has very good time resolution (50 ps) and high dynamic range (more than six orders of magnitude). In this paper, we describe our experimental setup, a series of tests to evaluate the system limitations using short pulse lasers on laboratory test benches, the existing SRS national X-ray facility, and the third-generation synchrotron radiation facility SLS. Taking all these results together, we are able to predict the system performance for Diamond.

Journal Keywords: Synchrotron; Bunch purity; TCSPC; Diamond light source; Lasers

Subject Areas: Technique Development


Technical Areas: Controls , Diagnostics

Added On: 10/11/2010 08:51

Discipline Tags:



Technical Tags: