Publication

Article Metrics

Citations


Online attention

Diamond Storage Ring Optical And X-Ray Diagnostics

DOI: 10.1063/1.1831146 DOI Help

Authors: Cyrille Thomas (Diamond Light Source) , Guenther Rehm (Diamond Light Source)
Co-authored by industrial partner: No

Type: Conference Paper
Conference: BEAM INSTRUMENTATION WORKSHOP 2004: Eleventh Beam Instrumentation Workshop
Peer Reviewed: No

State: Published (Approved)
Published: November 2004

Abstract: This paper gives an overview of the optical and X-ray diagnostics for the 3-GeV stored electron beam of the DIAMOND storage ring. The specification and the requirement for the diagnostics are given in detail. The diagnostics are performed using the properties of the synchrotron radiation from two bending magnets in the visible and in the X-ray range. Four measurements will provide information on the beam longitudinal distribution, the relative energy spread, the transverse size, and emittance of the beam.

Journal Keywords: Storage rings; Diamond; Bending magnet radiation; Electron beams; Synchrotron radiation

Subject Areas: Engineering


Technical Areas: Diagnostics

Added On: 01/12/2010 18:55

Discipline Tags:



Technical Tags: