Publication
Article Metrics
Citations
Online attention
Characterisation of HEXITECMHz - A 1 MHz continuous frame rate spectroscopic X-ray imaging detector system
DOI:
10.1016/j.nima.2023.168718
Authors:
B. D.
Cline
(UKRI STFC Rutherford Appleton Laboratory)
,
D.
Banks
(UKRI STFC Rutherford Appleton Laboratory)
,
S.
Bell
(UKRI STFC Rutherford Appleton Laboratory)
,
I.
Church
(UKRI STFC Rutherford Appleton Laboratory)
,
S.
Cross
(UKRI STFC Rutherford Appleton Laboratory)
,
A.
Davis
(UKRI STFC Rutherford Appleton Laboratory)
,
C.
Day
(UKRI STFC Rutherford Appleton Laboratory)
,
M.
French
(UKRI STFC Rutherford Appleton Laboratory)
,
T.
Gardiner
(UKRI STFC Rutherford Appleton Laboratory)
,
N.
Ghorbanian
(UKRI STFC Rutherford Appleton Laboratory)
,
J.
Harris
(UKRI STFC Rutherford Appleton Laboratory)
,
M.
Hart
(UKRI STFC Rutherford Appleton Laboratory)
,
J.
Holden
(UKRI STFC Rutherford Appleton Laboratory)
,
J.
Lipp
(UKRI STFC Rutherford Appleton Laboratory)
,
T.
Nicholls
(UKRI STFC Rutherford Appleton Laboratory)
,
J.
Nobes
(UKRI STFC Rutherford Appleton Laboratory)
,
S.
Pradeep
,
M.
Prydderch
(UKRI STFC Rutherford Appleton Laboratory)
,
M.
Roberts
(UKRI STFC Rutherford Appleton Laboratory)
,
A.
Schneider
(UKRI STFC Rutherford Appleton Laboratory)
,
P.
Seller
(UKRI STFC Rutherford Appleton Laboratory)
,
D.
Sole
(UKRI STFC Rutherford Appleton Laboratory)
,
M. C.
Veale
(UKRI STFC Rutherford Appleton Laboratory)
,
M. D.
Wilson
(UKRI STFC Rutherford Appleton Laboratory)
,
W.
Helsby
(UKRI STFC Daresbury Laboratory)
,
V.
Dhamgaye
(Diamond Light Source)
,
O.
Fox
(Diamond Light Source)
,
K.
Sawhney
(Diamond Light Source)
Co-authored by industrial partner:
No
Type:
Journal Paper
Journal:
Nuclear Instruments And Methods In Physics Research Section A: Accelerators, Spectrometers, Detectors And Associated Equipment
State:
Published (Approved)
Published:
September 2023
Diamond Proposal Number(s):
32772
Abstract: Spectroscopic X-ray imaging techniques including Compton X-ray Imaging, X-ray Fluorescence Imaging and Hyperspectral X-ray Tomography require energy-resolving detectors capable of operating at high incident X-ray fluxes to make time resolved measurements. HEXITECMHz, operates at a continuous 1 MHz frame rate and can make fully spectroscopic measurements at >106 ph s−1 mm−2. This is enabled by an integrating Front End, in-pixel digitisation and high-speed serialisers. A 300 μm thick p-type Si HEXITECMHz detector was characterised on the B16 Test Beamline at the Diamond Light Source and are the first measurements taken at a 1 MHz frame rate. At 10 keV and 15 keV) the device displayed average FWHM of 656 eV and 682 eV respectively, with minimal changes in spectroscopic performance over ∼8 h. Analysis of charge-sharing events show low charge loss and a linear energy-signal response. Higher-flux measurements illustrated the capability of the ASIC to operate as a photon-counting device.
Journal Keywords: Pixel detector; MHz imaging; P-type Si; Resolution; X-ray spectroscopy; X-ray imaging
Subject Areas:
Physics,
Engineering
Instruments:
B16-Test Beamline
Added On:
27/09/2023 08:30
Discipline Tags:
Detectors
Physics
Engineering & Technology
Technical Tags:
Diffraction