Publication
Article Metrics
Citations
Online attention
Electron diffraction data processing with DIALS
DOI:
10.1107/S2059798318007726
Authors:
Max T. B.
Clabbers
(University of Basel)
,
Tim
Gruene
(Paul Scherrer Institute)
,
James M.
Parkhurst
(Diamond Light Source)
,
Jan Pieter
Abrahams
(University of Basel)
,
David G.
Waterman
(CCP4; STFC)
Co-authored by industrial partner:
No
Type:
Journal Paper
Journal:
Acta Crystallographica Section D Structural Biology
, VOL 74
, PAGES 506 - 518
State:
Published (Approved)
Published:
June 2018
Open Access
Abstract: Electron diffraction is a relatively novel alternative to X-ray crystallography for the structure determination of macromolecules from three-dimensional nanometre-sized crystals. The continuous-rotation method of data collection has been adapted for the electron microscope. However, there are important differences in geometry that must be considered for successful data integration. The wavelength of electrons in a TEM is typically around 40 times shorter than that of X-rays, implying a nearly flat Ewald sphere, and consequently low diffraction angles and a high effective sample-to-detector distance. Nevertheless, the DIALS software package can, with specific adaptations, successfully process continuous-rotation electron diffraction data. Pathologies encountered specifically in electron diffraction make data integration more challenging. Errors can arise from instrumentation, such as beam drift or distorted diffraction patterns from lens imperfections. The diffraction geometry brings additional challenges such as strong correlation between lattice parameters and detector distance. These issues are compounded if calibration is incomplete, leading to uncertainty in experimental geometry, such as the effective detector distance and the rotation rate or direction. Dynamic scattering, absorption, radiation damage and incomplete wedges of data are additional factors that complicate data processing. Here, recent features of DIALS as adapted to electron diffraction processing are shown, including diagnostics for problematic diffraction geometry refinement, refinement of a smoothly varying beam model and corrections for distorted diffraction images. These novel features, combined with the existing tools in DIALS, make data integration and refinement feasible for electron crystallography, even in difficult cases.
Journal Keywords: electron microscopy; electron crystallography; protein nanocrystals; diffraction geometry; DIALS
Subject Areas:
Information and Communication Technology,
Biology and Bio-materials
Technical Areas:
Data acquisition
Added On:
12/06/2018 12:09
Documents:
rr5161.pdf
Discipline Tags:
Information & Communication Technologies
Structural biology
Data processing
Life Sciences & Biotech
Technical Tags: