I15-Extreme Conditions
|
Abstract: The emergence of antimicrobial resistant strains bacteria and a decline in the discovery of new antibiotics has led to the idea of combining various antimicrobials to treat resistant strains and/or polymicrobial infections. Metal oxide-doped glasses have been extensively investigated for their antimicrobial potential; however to date, most experiments have focused on single metal species in isolation. The present study investigates the antimicrobial potential of sodium calcium phosphates (P2O5)50(Na2O)20(CaO)30–X(MO)X, where M is cobalt, copper, or zinc as single species. In addition, this work studied the effect of co-doping glasses containing two different metal ions (Co + Cu, Co + Zn, and Cu + Zn). The antimicrobial efficacy of all glasses was tested against Gram-positive (Staphylococcus aureus) and Gram-negative (Escherichia coli) bacterial strains, as well as a fungal strain (Candida albicans). Minimum inhibitory and bactericidal concentrations and time kill/synergy assays were used to assess the antimicrobial activity. An enhanced antimicrobial effect, at 5 mg/mL concentration, was exhibited by cobalt, copper, and zinc oxide glasses alone and in combinations. A synergistic antimicrobial effect was observed by Cu + Co and Cu + Zn against E. coli and Cu + Zn against S. aureus.
|
Feb 2022
|
|
I16-Materials and Magnetism
|
Diamond Proposal Number(s):
[15319]
Abstract: Objective: The structure of the polymer phase of dental resin-based-composites is highly sensitive to photo-polymerisation variables. The objective of this study was to understand how different polymer structures, generated with different photo-polymerisation protocols, respond to thermal perturbation. Methods: Experimental resins were prepared from a series of Bis-GMA/TEGDMA blends (40/60, 50/50 and 60/40 wt.%), with either Camphorquinone/DMAEMA or Lucirin TPO as the photo-initiator system. Resins were photo-polymerised, in a disc geometry, at either relatively ‘high’ (3000 mW cm−2 for 6 s) or ‘low’ (300 mW cm−2 for 60 s) irradiances ensuring matched radiant exposures (18 J cm−2). Specimens were heated, from 20−160 °C at a rate of 5 °C min−1, whilst simultaneous synchrotron X-ray scattering measurements were taken at 5 °C increments to determine changes in polymer chain segment extension and medium-range order as a function of temperature. For each unique resin composition (n = 3), differential scanning calorimetry was used to measure glass transition temperatures using the same heating protocol. A paired t-test was used to determine significant differences in the glass transition temperature between irradiance protocols and photo-initiator chemistry at ɑ = 0.05. Results: Resins pre-polymerised through the use of TPO and or high irradiances demonstrated a reduced rate of chain extension indicative of lower thermal expansion and a larger decrease in relative order when heated below the glass transition temperature. Above the transition temperature, differences in the rate of chain extension were negligible, but slower converted systems showed greater relative order. There was no significant difference in the glass transition temperature between different photo-initiator systems or irradiance protocols.
|
Jan 2020
|
|
I16-Materials and Magnetism
I22-Small angle scattering & Diffraction
|
Diamond Proposal Number(s):
[11687, 14117, 15319]
Open Access
Abstract: The influence of reaction rate on the evolving polymer structure of photo-activated dimethacrylate biomedical resins was investigated using neutron and in situ synchrotron X-ray scattering with simultaneous Fourier-transform-near-infrared spectroscopy. Previous studies have correlated the degree of reactive group conversion with mechanical properties, but the impact of polymerization rate on the resultant polymer structure is unknown. Here, we demonstrate that the medium-range structural order at the functional end groups of these materials is dependent on the reaction rate. Accelerating polymerization increases correlation lengths in the methacrylate end groups but reduces the medium-range structural order per converted vinyl bond when compared with more slowly polymerized systems. At faster rates of polymerization, the conformation of atoms at the reacting end group can become fixed into the polymer structure at the onset of autodeceleration, storing residual strain. Neutron scattering confirms that the structural differences observed are reproduced at longer length scales. This effect is not as prominent in systems polymerized at slower rates despite similar final degrees of reactive group conversion. Results suggest that current interpretations of these materials, which extrapolate mechanical properties from conversion, may be incomplete. Accelerating polymerization can introduce structural differences, which will dictate residual strain and may ultimately explain the discrepancies in the predictive modeling of the mechanical behavior of these materials using conventional techniques.
|
Jul 2019
|
|
I14-Hard X-ray Nanoprobe
I18-Microfocus Spectroscopy
|
Open Access
Abstract: Biological exposures to micro- and nano-scale exogenous metal particles generated as a consequence of in-service degradation of orthopaedic prosthetics can result in severe adverse tissues reactions. However, individual reactions are highly variable and are not easily predicted, due to in part a lack of understanding of the speciation of the metal-stimuli which dictates cellular interactions and toxicity. Investigating the chemistry of implant derived metallic particles in biological tissue samples is complicated by small feature sizes, low concentrations and often a heterogeneous speciation and distribution. These challenges were addressed by developing a multi-scale two-dimensional X-ray absorption spectroscopic (XAS) mapping approach to discriminate sub-micron changes in particulate chemistry within ex-vivo tissues associated with failed CoCrMo total hip replacements (THRs). As a result, in the context of THRs, we demonstrate much greater variation in Cr chemistry within tissues compared with previous reports. Cr compounds including phosphate, hydroxide, oxide, metal and organic complexes were observed and correlated with Co and Mo distributions. This variability may help explain the lack of agreement between biological responses observed in experimental exposure models and clinical outcomes. The multi-scale 2D XAS mapping approach presents an essential tool in discriminating the chemistry in dilute biological systems where speciation heterogeneity is expected.
|
Jun 2019
|
|
I15-1-X-ray Pair Distribution Function (XPDF)
|
Diamond Proposal Number(s):
[16079]
Open Access
Abstract: Bioactive glasses are important for biomedical and dental applications. The controlled release of key ions, which elicit favourable biological responses, is known to be the first key step in the bioactivity of these materials. Properties such as bioactivity and solubility can be tailored for specific applications. The addition of fluoride ions is particularly interesting for dental applications as it promotes the formation of fluoro-apatite. To date there have been mixed reports in the literature on how fluorine is structurally incorporated into bioactive glasses. To optimize the design and subsequent bioactivity of these glasses, it is important to understand the connections between the glass composition, structure and relevant macroscopic properties such as apatite formation and glass degradation in aqueous media. Using neutron diffraction, high energy X-ray diffraction, 29Si NMR, FTIR and XPS we have investigated the atomic scale structure of mixed calcium oxide / calcium fluoride silicate based bioactive glasses. No evidence of direct Si-F bonding was observed, instead fluorine was found to bond directly to calcium resulting in mixed oxygen/fluoride polyhedra. It was therefore concluded that the addition of fluorine does not depolymerise the silicate network and that the widely used network connectivity models are valid in these oxyfluoride systems.
|
Jan 2019
|
|
I15-1-X-ray Pair Distribution Function (XPDF)
|
Diamond Proposal Number(s):
[16079]
Abstract: Bioactive phosphate glasses are of considerable interest for a range of soft and hard tissue engineering applications. The glasses are degradable and can release biologically important ions in a controlled manner. The glasses can also potentially be used as an antimicrobial delivery system. In the given study, novel cobalt doped phosphate-based glasses, (P2O5)50(Na2O)20(CaO)30-x(CoO)x where 0 ≤ x (mol%) ≤ 10, were manufactured and characterised. As the cobalt oxide concentration increased the rate of dissolution was observed to decrease. The antimicrobial potential of the glasses was studied using direct and indirect contact methods against both Escherichia coli (NCTC 10538) Staphylococcus aureus (ATCC 6538) and Candida albicans (ATCC 76615). The results showed a strong, time dependent and strain specific, antimicrobial activity of the glasses against microorganisms when in direct contact. Antimicrobial activity (R) ≥ 2 was observed within 2 hours against Escherichia coli whereas similar effect was achieved in 6 hours against Staphylococcus aureus and Candida albicans. However, when in indirect contact, the dissolution products from the bioactive glasses failed to show antimicrobial effect. Following direct exposure to the glasses for 7 days, osteoblast-like SAOS-2 cells showed a 5-fold increase in VEGF mRNA whilst THP-1 monocytic cells showed a 4-fold increase in VEGF mRNA expression when exposed to 10% CoO doped glass compared with the cobalt free control glass. Endothelial cells stimulated with conditioned medium taken from cell cultures of THP-1 monocytes exposed to 10% CoO doped glass showed clear tube–like structure (blood vessel) formation after 4 hours
|
Nov 2018
|
|
I18-Microfocus Spectroscopy
|
Alexander
Morrell
,
J. Frederick W.
Mosselmans
,
Kalotina
Geraki
,
Konstantin
Ignatyev
,
Hiram
Castillo-Michel
,
Peter
Monksfield
,
Adrian T.
Warfield
,
Maria
Febbraio
,
Helen M.
Roberts
,
Owen
Addison
,
Richard A.
Martin
Diamond Proposal Number(s):
[16458]
Abstract: Synchrotron radiation X-ray fluorescence microscopy is frequently used to investigate the spatial distribution of elements within a wide range of samples. Interrogation of heterogeneous samples that contain large concentration ranges has the potential to produce image artefacts due to the profile of the X-ray beam. The presence of these artefacts and the distribution of flux within the beam profile can significantly affect qualitative and quantitative analyses. Two distinct correction methods have been generated by referencing the beam profile itself or by employing an adaptive-thresholding procedure. Both methods significantly improve qualitative imaging by removing the artefacts without compromising the low-intensity features. The beam-profile correction method improves quantitative results but requires accurate two-dimensional characterization of the X-ray beam profile.
|
Nov 2018
|
|
B16-Test Beamline
|
Diamond Proposal Number(s):
[4016]
Abstract: Objectives: To measure the spatial distribution of crystallographic strain in tooth enamel induced by the photo-polymerisation of a dimethacrylate resin based composite cavity restoration. Methods: Six sound first premolar teeth, allocated into two groups (n = 3), were prepared with mesio-occlusal distal cavities. The enamel was machined at the point of maximum convexity on the outer tooth to create a vertical fin of thickness 100 μm and 0.5 mm depth to allow for synchrotron X-ray diffraction measurements. 2D diffraction patterns were used to determine crystallite orientation and quantify changes in the hydroxyapatite crystal lattice parameters, before and after photo-polymerisation of a composite material placed in the cavity, to calculate strain in the respective axis. The composite was photo-polymerised with either relatively high (1200 mW cm−2, group 1) or low (480 mW cm−2, group 2) irradiances using LED or quartz halogen light sources, respectively. A paired t-test was used to determine significant differences in strain between irradiance protocols at ɑ = 0.001. Results: Photo-polymerisation of the composite in the adjacent cavity induced significant changes in both the crystallographic c and a axes of the enamel measurement area. However the magnitude of strain was low with ∼0.1% difference before and after composite photo-polymerisation. Strain in enamel was not uniformly distributed and varied spatially as a function of crystallite orientation. Increased alignment of crystallites perpendicular to the cavity wall was associated with higher c axis strain. Additionally, strain was significantly greater in the c (p < 0.001) and a axis (p < 0.001) when using a high irradiance photo-polymerisation protocol. Significance: Although cuspal deflection is routinely measured to indirectly assess the ‘global’ effect of composite shrinkage on the tooth-restoration complex, here we show that absolute strains generated in enamel are low, indicating strain relief mechanisms may be operative. The use of low irradiance protocols for photo-polymerisation resulted in reduced strain.
|
Aug 2018
|
|
B16-Test Beamline
|
Diamond Proposal Number(s):
[11645]
Abstract: Defining the mechanisms underlying the programming of early life growth is fundamental for improving adult health and wellbeing. While the association between maternal diet, offspring growth and adult disease risk is well-established, the effect of father's diet on offspring development are largely unknown. Therefore, we fed male mice an imbalanced low protein diet (LPD) to determine the impact on post-fertilisation development and fetal growth. We observed that in preimplantation embryos derived from LPD fed males, expression of multiple genes within the central metabolic AMPK pathway was reduced. In late gestation, paternal LPD programmed increased fetal weight, however, placental weight was reduced, resulting in an elevated fetal:placental weight ratio. Analysis of gene expression patterns revealed increased levels of transporters for calcium, amino acids and glucose within LPD placentas. Furthermore, placental expression of the epigenetic regulators Dnmt1 and Dnmt3L were increased also, coinciding with altered patterns of maternal and paternal imprinted genes. More strikingly, we observed fetal skeletal development was perturbed in response to paternal LPD. Here, while offspring of LPD fed males possessed larger skeletons, their bones comprised lower volumes of high mineral density in combination with reduced maturity of bone apatite. These data offer new insight in the underlying programming mechanisms linking poor paternal diet at the time of conception with the development and growth of his offspring.
|
Feb 2017
|
|
I18-Microfocus Spectroscopy
|
Diamond Proposal Number(s):
[8251]
Open Access
Abstract: Quaternary phosphate-based glasses in the P2O5–CaO–Na2O–TiO2 system with a fixed P2O5 and CaO content of 40 and 25 mol% respectively have been successfully synthesised via sol–gel method and bulk, transparent samples were obtained. The structure, elemental proportion, and thermal properties of stabilised sol–gel glasses have been characterised using X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDX), 31P nuclear magnetic resonance (31P NMR), titanium K-edge X-ray absorption near-edge structure (XANES), fourier transform infrared (FTIR) spectroscopy, and differential thermal analysis (DTA). The XRD results confirmed the amorphous nature for all stabilized sol–gel derived glasses. The EDX result shows the relatively low loss of phosphorus during the sol–gel process and Ti K-edge XANES confirmed titanium in the glass structure is in mainly six-fold coordination environment. The 31P NMR and FTIR results revealed that the glass structure consist of mainly Q1 and Q2 phosphate units and the Ti4+ cation was acting as a cross-linking between phosphate units. In addition DTA results confirmed a decrease in the glass transition and crystallisation temperature with increasing Na2O content. Ion release studies also demonstrated a decrease in degradation rates with increasing TiO2 content therefore supporting the use of these glasses for biomedical applications that require a degree of control over glass degradation. These sol–gel glasses also offer the potential to incorporate proactive molecules for drug delivery application due to the low synthesis temperature employed.
|
Nov 2014
|
|